CLEAN T50 Ion/pH/ORP Multifunctional Meter
T50 Ion/pH/ORP Multifunctional Meter
T50 Ion/pH/ORP Multifunctional Meter
Three modes: ion concentration, pH, ORP
Detect Anytime Anywhere,Quick Accurate and Stable
Three modes: ion concentration, pH, ORP
Three types of electrode combinations are available for selection
Color screen, easy to understand, can display potential difference
The appearance design of the wine glass provides a stable and comfortable grip
Measurement data storage, available for output and use
Selection of matching electrodes:For more detailed information, please contact us

Ion Model Range ppm membrane pH range
Fluoride CS6210F 0.02 –20000 Solid 5-8
Chloride CS6210CL 1 –35,500 Solid 2-12
Ammonium CS6210NH4 0.1 –18000 PVC 4-10
Ammonia CS6212NH3 0.01 –17000 Gas >11
Nitrite CS6212NO2 0.2 –220 Gas 1.1-1.7
Carbon CS6212CO2 10-100000 Gas 4.8-5.2
Nitrate CS6210NO3 0.5 –62,000 PVC 2.5-11
Nitrite CS6210NO2 10 –2200 PVC 2-12
Potassium CS6210K 0.7 –98,000 PVC 2-12
Sodium CS6210Na 0.02-100000 PVC 5-12
Calcium CS6210CA2 0.2 - 40,000 PVC 3 - 10
Copper CS6210CU2 0.064-6,400 Solid 2-12
Ferrous CS6210Fe2 0-1000 PVC  

Parameter: Model pH:CS1030 pH:CS1048 ORP:CS2010 ORP:CS2048
Range 0-14 0-14 ±2000mV ±2000mV
Temp. range 0 - 80 °C 0 - 100 °C 0 - 80 °C 0 - 100 °C
Max pressure 2 bar (atm) 5 bar (atm) 2 bar (atm) 5 bar (atm)
Ref  system Ag/AgCl KCl Ag/AgCl KCl Ag/AgCl KCl Ag/AgCl KCl
salt bridge Double Double Double Double
Liquid interface Double sand core Circular ceramics Double sand core Circular ceramics
Reference Liquid gel Solid gel Liquid gel Solid gel
Sensitive film B11 Blue UV resistant platinum sheet Platinum ring
Shell material PC Glass PC Glass
Temp. sensor 10k 10k - -
Size 12*120mm 12*120mm 12*120mm 12*120mm
Cable/Terminal 1m,BNC 1m,BNC 1m,BNC 1m,BNC
Ion measurement range 0.00~100000mg/L(ppm)--- Based on the electrode
resolution 0.01~1
measurement accuracy ±0.5mV
calibration point 0.01,0.1,1,10,100,1000,10000 ppm
pH measurement range 0.00-14.00pH
resolution 0.01pH
indication error ±0.02pH
Up to 5 calibration points NIST: 1.68,4.01,6.86,9.18,12.45
Up to 5 calibration points USA: 1.68,4.01,7.00,10.01,12.45
ORP measurement range -2000mV-2000mV
resolution 1mV
indication error ±0.2%FS
calibration point Calibration at any one or two points
Temp. measurement range -10℃-110℃
resolution 0.1℃
indication error ±0.2℃
Powersupply power supply 1800mA lithium battery
battery charging Type-C plug, charging input: 4.2V, 1A
other Usage environment -5℃-60℃; Relative humidity<90%
Data storage/output 256 sets, Type-C interface output
Dimensions 183*76*33mm (length, width, height)
weight 260 grams
Site Meter